NYCY-FR 0.6/1 kV Flame Retardant Power Cable – VDE 0276 part 603

The NYCY-FR 0.6/1 kV cable delivers dependable power distribution for industrial, domestic, and underground applications. Constructed with copper conductors, PVC flame retardant insulation, a concentric copper conductor, and a black flame retardant PVC outer sheath, it offers exceptional fire safety and mechanical protection. Because it meets VDE 0276 part 603 standards and is CE/RoHS compliant, it provides a safe and reliable solution for power plants, switching installations, and secondary networks.

Application
NYCY-FR cables provide reliable transfer and distribution of electrical power in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they require no propagation of flames, installers use them in power plants, industrial and switching installations, and street lighting. Furthermore, they excel in domestic power supply connections and secondary distribution networks. Additionally, they are preferably used for underground application and as interior installation in rooms and cable ducts. Finally, they are suitable for outdoor applications where greater mechanical protection against accidental contact is required.

Cable construction
This cable strictly adheres to VDE 0276 part 603 standards. It features solid or multi-strand copper wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses a PVC flame retardant compound of degree of flame retardancy according to VDE 0293. Additionally, tapes and a filling compound form the inner sheath. Finally, a black PVC flame retardant outer sheath of degree of flame retardancy category A protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of Uo/U 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for single-core cables, or 12 times for multi-core cables. Furthermore, it passes the flame retardancy test according to BDS IEC 332-3, Category A.

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black. Double core cables feature light blue and brown. Multi-core configurations include specific color sequences for easy identification. For instance, 3-core uses brown, black, and grey. 4-core uses light blue, brown, black, and grey.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data NYCY-FR 0.6/1 kV

Number of wires and nominal cross section Shape Concentric conductor cross section Outer diameter approx. Cu weight Cable weight approx.
N x mm² mm² mm kg/km kg/km
1 x 1,5/1,5 re 1,5 7,9 27 98
1 x 2,5/2,5 re 2,5 8,5 41 122
1 x 4/4 re 4,0 9,4 61 163
1 x 6/6,0 re 6,0 9,8 108 203
1 x 10/10 re 10 11,3 182 286
1 x 16/16 re 16 12,9 272 380
1 x 25/25 rm 25 12,9 465 606
1 x 35/35 rm 35 16,4 653 807
2 x 1,5/1,5 re 1,5 13,0 65 229
2 x 2,5/2,5 re 2,5 13,7 88 270
2 x 4,0/4,0 re 4,0 15,0 110 375
2 x 6/6 re 6,0 15,5 177 420
2 x 10/10 re 10 19,1 274 619
2 x 16/16 rm 16 21,0 483 841
2 x 25/25 rm 25 26,1 729 1276
2 x 35/35 rm 35 27,8 1080 1642
2 x 50/50 rm 50 31,5 1341 2193
3 x 1,5 re – 13,1 90 230
3 x 2,5/2,5 re 2,5 14,3 90 305
3 x 4,0/4,0 re 4,0 16,6 147 425
3 x 6,0/6,0 re 6,0 16,7 242 428
3 x 10/10 re 10 20,0 365 724
3 x 16/16 rm 16 22,1 580 999
3 x 25/25 rm 25 26,6 938 1524
3 x 35/35 rm 35 29,1 1127 1813
3 x 50/50 sm 50 33,4 1827 2467
3 x 70/35 sm 35 32,7 1581 2415
3 x 70/70 sm 70 37,7 2333 3144
3 x 95/50 sm 50 38,6 2194 2800
3 x 95/95 sm 95 44,4 3161 4215
3 x 120/70 sm 70 45,2 2883 4004
3 x 120/120 sm 120 49,7 4038 5120
3 x 150/70 sm 70 45,8 3151 4360
3 x 150/150 sm 150 54,6 5043 6392
3 x 185/95 sm 95 53,9 6051 7329
3 x 185/185 sm 185 60,0 7506 9294
4 x 1,5/1,5 re 1,5 14,3 70 284
4 x 2,5/2,5 re 2,5 15,5 113 375
4 x 4,0/4,0 re 4,0 17,8 193 494
4 x 6,0/6,0 re 6,0 20,0 297 620
4 x 10/10 re 10 21,5 457 860
4 x 16/16 rm 16 23,5 708 1124
4 x 25/16 rm 16 29,0 1090 1764
4 x 35/16 rm 16 32,0 1365 2077
4 x 50/25 sm 25 38,4 1855 2910
4 x 70/35 sm 35 41,9 2471 3730
4 x 95/50 sm 50 46,4 3531 5054
4 x 120/70 sm 70 48,3 4221 5898
4 x 150/70 sm 70 52,3 4691 7365
4 x 185/95 sm 95 55,3 6214 7548
4 x 240/120 sm 120 62,3 8256 9374

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the NYCY-FR cable?
A:- It is used for power transfer and distribution in power plants, industrial and switching installations, street lighting, domestic power supply connections, and secondary distribution networks.

Q:- What are the key features of this cable’s fire safety?
A:- It features a PVC flame retardant insulation and a black PVC outer sheath with a flame retardancy category A, passing the BDS IEC 332-3 test.

Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0276 part 603 standards, and the conductor complies with VDE 0295 (IEC 60228).

Q:- What is the function of the concentric conductor?
A:- The concentric conductor provides a reliable earth path and enhances mechanical protection for the cable.

Q:- What type of conductor and insulation does it use?
A:- It uses solid or multi-strand Cu wires (class 1 or 2) with PVC flame retardant insulation.

Q:- What is the nominal voltage and maximum conductor temperature?
A:- The rated voltage is Uo/U 0.6/1 kV, and the maximum conductor temperature is +70°C.

Q:- What is the short-circuit temperature limit?
A:- It can withstand a short circuit temperature of +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV at 50 Hz.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter for single-core cables and 12 times for multi-core cables.

Q:- What is the color coding for the 4-core variant?
A:- The 4-core variant features light blue, brown, black, and grey colors.

Reviews

There are no reviews yet.

Be the first to review “NYCY-FR 0.6/1 kV Flame Retardant Power Cable – VDE 0276 part 603”

Your email address will not be published. Required fields are marked *