NYYfr-O/J 0.6/1 kV Flame Retardant Power Cable – VDE 0276 part 603
The NYYfr-O/J 0.6/1 kV cable delivers dependable power distribution for industrial, domestic, and lighting applications. Constructed with copper conductors, PVC flame retardant insulation, and a black flame retardant PVC outer sheath, it offers exceptional fire safety and durability. Because it meets VDE 0276 part 603 standards and is CE/RoHS compliant, it provides a safe and reliable solution for power plants, switching installations, and secondary networks.
Application
NYYfr-O/J cables provide reliable transfer and distribution of electrical power in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they require no perforation of false ceilings, installers use them widely in power plants, industrial and switching installations, and street lighting. Furthermore, they excel in domestic power supply connections and secondary distribution networks. Consequently, they deliver consistent and safe performance in demanding environments.
Cable construction
This cable strictly adheres to VDE 0276 part 603 standards. It features solid or multi-strand copper wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses a PVC flame retardant compound of degree of flame retardancy according to VDE 0293. Additionally, tapes and a filling compound form the inner sheath. Finally, a black PVC flame retardant outer sheath of degree of flame retardancy category A protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of Uo/U 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for single-core cables, or 12 times for multi-core cables. Furthermore, it passes the flame retardancy test according to BDS IEC 332-3/82, Category A.
Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black or yellow/green. Double core cables feature light blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences for easy identification. For instance, 3-core uses brown, black, grey, or yellow/green, light blue, brown. 4-core uses light blue, brown, black, grey, or yellow/green, brown, black, grey. 5-core uses light blue, brown, black, grey, black, or yellow/green, light blue, brown, black, grey. Multiple core uses black with number marking on cores or black with number mark on cores and yellow/green core in the outer cover.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data NYYfr-O/J 0.6/1 kV
| Number of conductors and nominal cross section | Form of conductor | Cable diameter approx. | Mass of Cu | Mass of cable approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 1 x 1,5 | re | 7,1 | 14 | 63 |
| 1 x 2,5 | re | 7,8 | 23 | 80 |
| 1 x 4,0 | re | 8,4 | 37 | 104 |
| 1 x 6,0 | re | 8,9 | 56 | 128 |
| 1 x 10,0 | re | 9,9 | 94 | 183 |
| 1 x 16,0 | re | 10,7 | 149 | 249 |
| 1 x 25,0 | rm | 12,7 | 243 | 359 |
| 1 x 35,0 | rm | 13,9 | 337 | 463 |
| 1 x 50,0 | rm | 15,4 | 480 | 633 |
| 1 x 70,0 | rm | 17,1 | 656 | 817 |
| 1 x 95,0 | rm | 19,4 | 911 | 1092 |
| 1 x 120,0 | rm | 20,8 | 1121 | 1326 |
| 1 x 150,0 | rm | 22,7 | 1415 | 1627 |
| 1 x 185,0 | rm | 25,0 | 1770 | 2013 |
| 1 x 240,0 | rm | 27,8 | 2273 | 2553 |
| 1 x 300,0 | rm | 30,7 | 2872 | 3200 |
| 1 x 400,0 | rm | 34,1 | 3693 | 4148 |
| 1 x 500,0 | rm | 38,1 | 4725 | 5141 |
| 2 x 1,5 | re | 12,2 | 28 | 192 |
| 2 x 2,5 | re | 12,9 | 46 | 219 |
| 2 x 4,0 | re | 14,9 | 75 | 315 |
| 2 x 6,0 | re | 15,8 | 112 | 355 |
| 2 x 10,0 | re | 16,4 | 188 | 419 |
| 2 x 16,0 | rm | 19,4 | 298 | 676 |
| 2 x 25,0 | rm | 23,5 | 485 | 1027 |
| 2 x 35,0 | rm | 25,9 | 673 | 1265 |
| 2 x 50,0 | rm | 29,1 | 903 | 1703 |
| 2 x 70,0 | rm | 33,6 | 1812 | 2393 |
| 3 x 1,5 | re | 12,1 | 43 | 201 |
| 3 x 2,5 | re | 12,9 | 70 | 247 |
| 3 x 4,0 | re | 15,0 | 112 | 350 |
| 3 x 6,0 | re | 16,1 | 168 | 435 |
| 3 x 10,0 | re | 18,0 | 252 | 556 |
| 3 x 16,0 | rm | 20,1 | 447 | 828 |
| 3 x 25,0 | rm | 24,4 | 728 | 1250 |
| 3 x 35,0 | rm | 26,7 | 1010 | 1638 |
| 3 x 50,0 | rm | 30,4 | 1353 | 2139 |
| 3 x 70,0 | rm | 37,7 | 1968 | 2398 |
| 3 x 95,0 | sm | 32,9 | 2685 | 3082 |
| 3 x 120,0 | sm | 35,4 | 3440 | 3962 |
Construction data NYYfr-O/J 0.6/1 kV
| Number of conductors and nominal cross section | Form of conductor | Cable diameter approx. | Mass of Cu | Mass of cable approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 3 x 150,0 | sm | 39,2 | 4245 | 4867 |
| 3 x 185,0 | sm | 42,7 | 5311 | 5789 |
| 3 x 240,0 | sm | 48,1 | 6981 | 7689 |
| 3 x 300,0 | sm | 53,5 | 8861 | 9702 |
| 3 x 50,0+25 | sm | 29,4 | 1605 | 2091 |
| 3 x 70,0+35 | sm | 33,6 | 2304 | 2800 |
| 3 x 95,0+50 | sm | 37,8 | 3187 | 3934 |
| 3 x 120,0+70 | sm | 40,9 | 4096 | 4779 |
| 3 x 150,0+70 | sm | 45,2 | 5001 | 5685 |
| 3 x 185,0+95 | sm | 49,2 | 6222 | 7091 |
| 3 x 240,0+120 | sm | 55,3 | 8128 | 9227 |
| 4 x 1,5 | re | 13,8 | 57 | 252 |
| 4 x 2,5 | re | 15,0 | 93 | 289 |
| 4 x 4,0 | re | 16,2 | 149 | 419 |
| 4 x 6,0 | re | 17,6 | 223 | 533 |
| 4 x 10,0 | re | 19,5 | 376 | 741 |
| 4 x 16,0 | rm | 21,8 | 595 | 1024 |
| 4 x 25,0 | rm | 27,2 | 970 | 1615 |
| 4 x 35,0 | rm | 30,1 | 1325 | 1893 |
| 4 x 50,0 | sm | 34,4 | 1817 | 2348 |
| 4 x 70,0 | sm | 37,8 | 2624 | 3142 |
| 4 x 95,0 | sm | 42,2 | 3587 | 4256 |
| 4 x 120,0 | sm | 45,3 | 4467 | 5010 |
| 4 x 150,0 | sm | 50,0 | 5503 | 6446 |
| 4 x 185,0 | sm | 55,3 | 6860 | 7939 |
| 4 x 240,0 | sm | 62,0 | 9306 | 10259 |
| 5 x 1,5 | re | 13,7 | 71 | 272 |
| 5 x 2,5 | re | 15,0 | 116 | 341 |
| 5 x 4,0 | re | 17,7 | 187 | 459 |
| 5 x 6,0 | re | 19,0 | 279 | 505 |
| 5 x 10,0 | re | 21,6 | 470 | 911 |
| 5 x 16,0 | rm | 24,1 | 744 | 1213 |
| 5 x 25,0 | rm | 30,0 | 1213 | 1900 |
| 5 x 35,0 | rm | 33,1 | 1683 | 2309 |
| 5 x 50,0 | sm | 37,1 | 2271 | 3435 |
| 5 x 70,0 | sm | 43,6 | 3203 | 4063 |
| 5 x 95,0 | sm | 50,1 | 4554 | 6318 |
Factory Overview
Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the NYYfr-O/J cable?
A:- It is used for power transfer and distribution in power plants, industrial and switching installations, street lighting, domestic power supply connections, and secondary distribution networks.
Q:- What are the key features of this cable’s fire safety?
A:- It features a PVC flame retardant insulation and a black PVC outer sheath with a flame retardancy category A, passing the BDS IEC 332-3/82 test.
Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0276 part 603 standards, and the conductor complies with VDE 0295 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses solid or multi-strand Cu wires (class 1 or 2) with PVC flame retardant insulation.
Q:- What is the nominal voltage and maximum conductor temperature?
A:- The rated voltage is Uo/U 0.6/1 kV, and the maximum conductor temperature is +70°C.
Q:- What is the short-circuit temperature limit?
A:- It can withstand a short circuit temperature of +160°C for no more than 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV at 50 Hz.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter for single-core cables and 12 times for multi-core cables.
Q:- What is the color coding for the 3-core variant?
A:- The 3-core variant features brown, black, grey or yellow/green, light blue, and brown colors.
Q:- Is this cable RoHS and CE compliant?
A:- Yes, the product is both RoHS and CE compliant.