SAH-20 / SAX / SAHV-20 12/20 kV XLPE Overhead Cable – FN KI 02.004
The SAH-20, SAX, and SAHV-20 12/20 kV cables deliver dependable power transfer and distribution for overhead electrical networks. Constructed with aluminum alloy or steel-reinforced aluminum conductors, XLPE insulation, and a black outer covering, they offer excellent resistance to atmospheric overvoltages. Because they meet FN KI 02.004 and SFS 5791/94 standards, they provide a reliable solution for overhead lines, particularly in terrain where space is limited.
Application
SAH-20, SAX, and SAHV-20 power cables provide reliable transfer and distribution of electrical power in overhead electrical networks. They operate efficiently at a nominal voltage of Uo/U 12/20 kV and a frequency of 50 Hz. Because these cables feature XLPE insulation and overhead conductors, they offer low susceptibility to operational faults caused by atmospheric overvoltages. Furthermore, they are less dependent on the space in the terrain required for the line, especially in cases of parallel lines. Consequently, they deliver consistent performance in demanding infrastructure environments.
Cable construction
This cable strictly adheres to FN KI 02.004 and SFS 5791/94 standards. It features Al alloy conductors (stranded compacted) or steel-reinforced Al stranded compacted conductors (type AC) according to FN KI 02.004. The insulation uses XLPE with a minimum 2% carbon black content. Additionally, longitudinal water blocking is provided by agreement between the manufacturer and the purchaser. The color is black. The marking is SAH-20 according to FN KI 02 004, SAH-20 to FN KI 02 004 with longitudinal water blocking features, and SAX according to SFS 5791/94.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains an operating temperature of 90 °C. The short-circuit temperature reaches 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 12/20 kV (6/10 kV) at 50 Hz. The highest system voltage is not more than 24 kV. Test voltage is 4 kV for 5 minutes. The minimum bending radius is 10 times the cable diameter. The temperature of laying is no less than -20 °C, with a recommended installation temperature of 15 °C.
Constructive and Electrical Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and current carrying capacity.
Construction and electrical data
| Nominal cross-section of a wire in a conductor | Number of conductor | Nominal diameter of conductor | Nominal thickness of covering | Approximate overall diameter | Mass of cable approx. | Breaking load min. | Resistance at 20°C max. | Current carrying capacity | Short circuit current for 1 s |
|---|---|---|---|---|---|---|---|---|---|
| mm² | N | mm | mm | mm | kg/km | kN | Ω/km | A | kA |
| 35/Alm | 7 | 7.0±0.20 | 2,3 | 11,6 | 120 | 11,2 | 0,868 | 189 | 3,2 |
| 50/Alm | 7 | 8.0±0.20 | 2,3 | 12,6 | 200 | 14,2 | 0,720 | 245 | 4,35 |
| 70/Alm | 7 | 9.7±0.25 | 2,3 | 14,3 | 270 | 20,6 | 0,493 | 300 | 6,85 |
| 95/Alm | 19 | 11.3±0.3 | 2,3 | 16,9 | 279 | 27,9 | 0,363 | 370 | 8,908 |
| 120/Alm | 19 | 12.4±0.3 | 2,3 | 17,9 | 350 | 35,2 | 0,283 | 425 | 11,70 |
| 150/Alm | 19 | 14.2±0.3 | 2,3 | 18,8 | 510 | 43,4 | 0,236 | 495 | 14,50 |
| 35/AcMm | 7 | 7.0±0.20 | 2,3 | 11,6 | 205 | 11,2 | 0,868 | 195 | 3,2 |
| 50/AcMm | 7 | 8.0±0.20 | 2,3 | 12,6 | 250 | 14,2 | 0,720 | 245 | 4,35 |
| 70/AcMm | 7 | 9.7±0.25 | 2,3 | 14,3 | 340 | 20,6 | 0,493 | 300 | 6,85 |
| 95/AcMm | 19 | 11.3±0.3 | 2,3 | 17,3 | 370 | 35,2 | 0,363 | 370 | 8,908 |
| 120/AcMm | 19 | 12.4±0.3 | 2,3 | 17,4 | 470 | 35,2 | 0,283 | 425 | 11,70 |
| 150/AcMm | 19 | 14.2±0.3 | 2,3 | 18,8 | 590 | 43,4 | 0,236 | 495 | 14,50 |
| *35/AcMm | 7 | 8,4 | 2,3 | 13,0 | 245 | 13,38 | 0,778 | 195 | 3,2 |
| *50/AcMm | 7 | 9,6 | 2,3 | 14,2 | 305 | 17,01 | 0,595 | 245 | 4,35 |
| *70/AcMm | 7 | 11,6 | 2,3 | 16,0 | 365 | 23,99 | 0,423 | 300 | 6,85 |
| *95/AcMm | 7 | 13,5 | 2,3 | 18,1 | 545 | 32,98 | 0,301 | 370 | 8,908 |
NOTE: * Conductors type AC according to BDS 1133.
Factory Overview
Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SAH-20/SAX/SAHV-20 cable?
A:- It is designed for the transfer and distribution of electrical power in overhead electrical networks with a nominal voltage of Uo/U 12/20 kV and a frequency of 50 Hz.
Q:- What are the key advantages of this overhead cable?
A:- The XLPE insulated overhead conductors offer low susceptibility to operational faults caused by atmospheric overvoltages and are less dependent on the space required in the terrain, especially for parallel lines.
Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.004 and SFS 5791/94 standards.
Q:- What type of conductor and insulation does it use?
A:- It uses Al alloy stranded compacted or steel-reinforced Al stranded compacted conductors (type AC) and XLPE insulation with a minimum 2% carbon black content.
Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage is 12/20 kV (6/10 kV) at 50 Hz, and the highest system voltage is not more than 24 kV.
Q:- What are the operating and short-circuit temperatures?
A:- The operating temperature is 90°C, and the short-circuit temperature reaches 250°C for a maximum of 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV for 5 minutes.
Q:- What is the minimum bending radius and laying temperature?
A:- The minimum bending radius is 10 times the cable diameter, and the temperature of laying is no less than -20°C with a recommended 15°C.
Q:- What is the purpose of the longitudinal water blocking feature?
A:- The longitudinal water blocking feature, which may be provided by agreement between the manufacturer and the purchaser, prevents water ingress along the length of the cable.
Q:- How are the cables marked for identification?
A:- The cables are marked as SAH-20 according to FN KI 02 004, SAH-20 to FN KI 02 004 with longitudinal water blocking features, and SAX according to SFS 5791/94.


Reviews
There are no reviews yet.