NAYCY 0.6/1 kV Aluminum Power Cable – Concentric Copper Conductor & VDE 0276
The NAYCY 0.6/1 kV cable delivers dependable power distribution for industrial and domestic applications. Constructed with solid or stranded aluminum conductors, PVC insulation, a unique concentric copper conductor, and a black PVC outer sheath, it offers exceptional mechanical protection. Because it meets strict VDE standards and is CE/RoHS compliant, it provides a safe and reliable solution for underground and outdoor installations.
Application
NAYCY cables provide reliable power distribution for industrial and switching installations. They also excel in street lighting and domestic power supply connections. Because of their robust design, installers prefer them for interior installations in rooms, cable ducts, and outdoor applications. Furthermore, they function well in the open air, underground, and in water. However, you must use them in environments that require mechanical protection against accidental contact or damage.
Cable construction
This cable strictly adheres to VDE 0276 part 603 standards. It features solid or multi-strand aluminum wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses PVC type DIV4 according to VDE0276, while core identification follows VDE 0293. Additionally, tapes and a filling compound form the inner sheath. A unique feature is the concentric conductor made of Cu wires and Cu tapes. Finally, a black PVC type DMV5 sheath (acc. VDE 0276) protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for single-core cables, or 12 times for multi-core cables. Furthermore, it passes the flame test according to VDE 0472 part 804 class B (IEC 332 part 1).
Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black. Double core cables feature blue and brown. Multi-core configurations include specific color sequences for easy identification.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data NAYCY 0.6/1 kV
| Number of wires and nominal cross section | Shape | Concentric conductor cross section | Outer diameter approx. | Al weight | Cu weight | Cable weight approx. |
|---|---|---|---|---|---|---|
| N x mm² | mm² | mm | kg/km | kg/km | kg/km | |
| 3 x 35,0 | re | 16 | 21,3 | 290 | 150 | 1143 |
| 3 x 50,0 | re | 25 | 24,5 | 410 | 230 | 1565 |
| 3 x 70,0 | se | 35 | 28,1 | 567 | 456 | 1875 |
| 3 x 95,0 | se | 50 | 33,1 | 768 | 454 | 2297 |
| 3 x 120,0 | se | 70 | 38,0 | 993 | 849 | 2715 |
| 3 x 70,0 | sm | 35 | 33,1 | 584 | 236 | 1489 |
| 3 x 95,0 | sm | 50 | 34,1 | 803 | 413 | 1648 |
| 3 x 120,0 | sm | 70 | 38,7 | 1099 | 584 | 2253 |
| 3 x 95,0 | sm | 50 | 35,7 | 809 | 580 | 2281 |
| 3 x 120,0 | sm | 70 | 40,0 | 1023 | 684 | 2654 |
| 3 x 150,0 | sm | 70 | 44,2 | 1257 | 832 | 2798 |
| 3 x 150,0 | sm | 95 | 45,4 | 1257 | 804 | 3164 |
| 3 x 185,0 | sm | 95 | 48,6 | 1579 | 890 | 3480 |
Note: Other core configuration and special constructions manufactured upon request.
Factory Overview
Packaging & Shipping

Frequently asked questions and answer
Q:- What is the primary application of the NAYCY cable?
A:- NAYCY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, and secondary distribution networks.
Q:- What are the main construction standards for this cable?
A:- The construction adheres to VDE 0276 part 603 standards, and the conductor complies with VDE 0295 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses solid or multi-strand Al wires class 1 or 2 for the main conductor and PVC type DIV4 for insulation.
Q:- What makes the NAYCY cable different from standard AYY cables?
A:- The NAYCY features a concentric conductor made of Cu wires and Cu tapes, providing enhanced mechanical protection and functioning as an earth conductor.
Q:- What is the rated voltage and test voltage?
A:- The rated voltage Uo/U is 0.6/1 kV, and it undergoes a test voltage of AC – 4 kV at 50 Hz.
Q:- What are the maximum conductor and short circuit temperatures?
A:- The maximum conductor temperature is +70°C, and it can withstand a short circuit temperature of +160°C for no more than 5 seconds.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter for single-core cables and 12 times for multi-core cables.
Q:- What is the color coding for single and double-core versions?
A:- Single core cables are black, while double core cables feature blue and brown colors.
Q:- What type of outer sheath protects the cable?
A:- A black PVC type DMV5 sheath (according to VDE 0276) protects the entire cable assembly.
Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to VDE 0472 part 804 class B (IEC 332 part 1).



Reviews
There are no reviews yet.