AGKABEL Halogen-Free Power Cables – N2XH-O/J

Heavy-duty, flame-retardant power cables designed for indoor installation in dry and wet zones, in/on/under plaster, and for outdoor use (not for direct burial). Features XLPE insulation and a halogen-free sheath for maximum safety. Compliant with DIN VDE 0276 part 604 and IEC 332-3. Nominal voltage: 0.6/1 kV. Available from 1 to 5 cores, 1.5mm² to 300mm².

AGKABEL GRUPPE LIMITED presents the Halogen-Free Power Cables N2XH-O/J, engineered for reliable energy distribution with superior fire safety. These cables utilize XLPE (Cross-linked Polyethylene) insulation, which allows for higher operating temperatures and greater current-carrying capacity compared to standard PVC cables. The halogen-free sheath ensures that in the event of a fire, the cable emits minimal smoke and no toxic corrosive gases, protecting both people and sensitive equipment. Designed for indoor installation in dry and wet zones, in, on, and under plaster, they are also suitable for outdoor installation (but not for direct laying below ground).

Technical Data

  • Standard: acc. to DIN VDE 0276 part 604

  • Nominal voltage U0/U: 0,6/1 kV

  • Flame-retardant: IEC 332-3

  • Application: For indoor installation in dry and wet zones, in, on and under plaster. Further use for outdoor installation. But not suitable for direct laying below ground.

Technical Specifications Table

N2XH-O (Single Core)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11601008 1X6 RE 9,8 58,00 95,00
11601010 1X10 RE 10,2 96,00 135,00
11601012 1X16 RM 12,2 154,00 200,00
11601005 1X4 RE 9,0 39,00 75,00
11601015 1X25 RM 14,3 240,00 295,00
11601018 1X35 RM 15,4 336,00 385,00
11601019 1X50 RM 15,8 480,00 510,00
11601020 1X70 RM 17,7 672,00 715,00
11601021 1X95 RM 20,2 912,00 960,00
11601022 1X120 RM 22,4 1.152,00 1.190,00
11601023 1X150 RM 24,4 1.440,00 1.470,00
11601024 1X185 RM 25,8 1.776,00 1.810,00
11601025 1X240 RM 28,6 2.304,00 2.360,00
11601026 1X300 RM 32,8 2.880,00 2.420,00

N2XH-J (Multicore)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11601104 1X4 RE 9,0 39,00 75,00
11601086 1X6 RE 9,8 58,00 95,00
11601013 1X16 RM 12,2 154,00 200,00
141601099 1X25 RM 14,3 240,00 295,00
11601094 1X35 RM 15,4 336,00 385,00
11601093 1X50 RM 15,8 480,00 510,00
11601100 1X70 RM 17,7 672,00 715,00
11601097 1X95 RM 20,2 912,00 960,00
11601098 1X120 RM 22,4 1.152,00 1.190,00
11601101 1X150 RM 24,4 1.440,00 1.470,00
11601102 1X185 RM 25,8 1.776,00 1.810,00
11601103 1X240 RM 28,6 2.304,00 2.360,00
11601095 1X300 RM 32,8 2.880,00 2.420,00
11601002 3X1,5 RE 11,0 43,00 129,00
11601004 3X2,5 RE 12,0 72,00 165,00
11601007 3X4 RE 13,0 115,00 225,00
11601027 3X6 RE 14,0 173,00 295,00
11601028 3X10 RE 16,0 288,00 440,00
11601029 3X16 RE 19,0 461,00 660,00
11601017 3X25 RM 24,0 720,00 1.010,00
11601066 3X25/16 RE o. r. 874,00 1.400,00
11601030 3X35 RM 27,0 1.008,00 1.330,00
11601067 3X35/16 RE o. r. 1.161,00 1.500,00
11601031 3X50 RM 29,0 1.440,00 1.765,00
11601038 3X50/25 RM 32,0 1.680,00 1.950,00
11601032 3X70 RM 33,0 2.016,00 –
11601039 3X70/35 RM 37,0 2.352,00 2.700,00
11601033 3X95 RM 37,0 2.736,00 3.300,00
11601040 3X95/50 RM 41,0 3.216,00 3.550,00
11601034 3X120 RM 41,0 3.456,00 4.050,00
11601041 3X120/70 RM 45,0 4.128,00 4.550,00
11601035 3X150 RM 45,0 4.320,00 4.900,00
11601042 3X150/70 RM 49,0 4.992,00 5.450,00
11601036 3X185 RM 50,0 5.328,00 5.100,00
11601037 3X240 RM 56,0 6.912,00 7.800,00

(Note: The multicore table appears to list single-core sizes at the top, followed by 3-core sizes. “o. r.” indicates “on request”. Further dimensions available on request.)

 

Factory Overview


Packaging & Shipping


Fly

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for these cables?
They are designed for indoor installation in dry and wet zones, and can be installed in, on, and under plaster. They are also suitable for outdoor installation but not for direct laying below ground.

2. What are the benefits of halogen-free construction?
Halogen-free cables are safer in fire situations as they do not emit toxic or corrosive halogen gases, and they produce minimal smoke, protecting people and sensitive equipment.

3. What are the benefits of XLPE insulation?
XLPE (Cross-linked Polyethylene) insulation offers superior dielectric strength, higher current-carrying capacity, and excellent resistance to thermal deformation, making these cables highly reliable for power distribution.

4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV.

5. What standard do these cables comply with?
They comply with DIN VDE 0276 part 604 and are flame-retardant according to IEC 332-3.

6. What sizes and core configurations are available?
Available from 1 to 5 cores, with conductor sizes ranging from 1.5mm² to 300mm².

 

 

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Halogen-Free Power Cables – N2XH-O/J”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS