AGKABEL Halogen-Free Circuit Integrity Cables – JE-H(St)H…Bd (FE 180 E30/E90)
High-performance, flame-resistant telecommunication cables designed for safety-critical systems. They maintain circuit integrity for 30 minutes (E30) or 90 minutes (E90) in the event of a fire, and meet the FE 180 standard for direct flame exposure. Designed for fixed installation with approved cable trays and clamps. Compliant with DIN VDE 0815 and IEC 332-3. Available in pair configurations from 2x2x0.8mm² to 52x2x0.8mm².
AGKABEL GRUPPE LIMITED presents the Halogen-Free Circuit Integrity Cables JE-H(St)H…Bd, engineered to ensure the continued operation of critical safety systems during a fire. These cables are essential for fire alarm systems, emergency lighting, passenger lifts, and smoke extraction systems. They are available in three specific performance classifications to meet various building safety requirements: E30, E90, and E30/E90 combined.
Technical Data
-
Standard: acc. to DIN VDE 0815
-
Flame-retardant: IEC 332-3
-
Application: Flame-resistant telecommunication cable with 30 or 90 min. of circuit integrity in case of fire. For fixed installation with approved cable trays and clamps.
-
FE 180: Insulation integrity for 180 minutes (Test acc. to DIN VDE 0472 part 814 = IEC 60331).
-
E30: Functionality of electrical cable systems for a minimum of 30 minutes (Test acc. to DIN VDE 4102 part 12). Ensures functionality for fire warning/alarm systems, safety lighting, passenger lifts with evacuation circuits, etc.
-
E90: Functionality of electrical cable systems for a minimum of 90 minutes (Test acc. to DIN VDE 4102 part 12). Ensures functionality for water-pressure-rising stations, smoke and heat extraction systems, fire department lifts, emergency lifts for sickbeds in hospitals, etc.
Technical Specifications Table
E30 Series
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11611001 | E30 2x2x0,8 | 7,5 | 25,00 | 65,00 |
| 11611002 | E30 4x2x0,8 | 12,5 | 45,00 | 103,00 |
| 11611003 | E30 8x2x0,8 | 15,0 | 85,00 | 165,00 |
| 11611004 | E30 12x2x0,8 | 18,0 | 126,00 | 235,00 |
| 11611005 | E30 16x2x0,8 | 20,0 | 166,00 | 300,00 |
| 11611006 | E30 20x2x0,8 | 22,0 | 206,00 | 361,00 |
| 11611007 | E30 32x2x0,8 | 24,5 | 327,00 | 553,00 |
| 11611008 | E30 40x2x0,8 | 28,5 | 407,00 | 671,00 |
| 11611009 | E30 52x2x0,8 | 30,5 | 528,00 | 865,00 |
E90 Series
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11612001 | E90 2x2x0,8 | 10,7 | 25,00 | 83,00 |
| 11612002 | E90 4x2x0,8 | 15,0 | 45,00 | 138,00 |
| 11612003 | E90 8x2x0,8 | 18,0 | 85,00 | 243,00 |
| 11612004 | E90 12x2x0,8 | 20,0 | 126,00 | 351,00 |
| 11612005 | E90 16x2x0,8 | 22,5 | 166,00 | 441,00 |
| 11612006 | E90 20x2x0,8 | 25,0 | 206,00 | 557,00 |
| 11612007 | E90 32x2x0,8 | 31,0 | 327,00 | 800,00 |
| 11612008 | E90 40x2x0,8 | 33,0 | 407,00 | 1.000,00 |
| 11612009 | E90 52x2x0,8 | 36,0 | 528,00 | 1.250,00 |
E30/E90 Series
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11613001 | E30/E90 2x2x0,8 | 9,0 | 25,00 | 135,00 |
| 11613010 | E30/E90 4x2x0,8 | 10,9 | 45,00 | 127,00 |
| 11613003 | E30/E90 8x2x0,8 | 14,5 | 85,00 | 232,00 |
| 11613004 | E30/E90 12x2x0,8 | 17,1 | 126,00 | 318,00 |
| 11613005 | E30/E90 16x2x0,8 | 19,6 | 166,00 | 430,00 |
| 11613006 | E30/E90 20x2x0,8 | 21,5 | 206,00 | 514,00 |
| 11613007 | E30/E90 32x2x0,8 | 27,0 | 327,00 | 730,00 |
| 11613008 | E30/E90 40x2x0,8 | 29,8 | 407,00 | 962,00 |
| 11613009 | E30/E90 52x2x0,8 | 33,2 | 527,00 | 1.200,00 |
Factory Overview

Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are essential for safety-critical systems that must remain operational during a fire, such as fire alarm systems, safety lighting, passenger lifts with evacuation circuits, smoke and heat extraction systems, and fire department lifts.
2. What is the difference between E30 and E90?
-
E30: Guarantees circuit integrity (functionality) for a minimum of 30 minutes during a fire.
-
E90: Guarantees circuit integrity for a minimum of 90 minutes, providing a longer window for evacuation and emergency operations.
3. What does “FE 180” mean?
FE 180 indicates that the cable maintains insulation integrity for 180 minutes under direct flame exposure (tested according to IEC 60331), ensuring it does not short-circuit even in extreme conditions.
4. What is the difference between the E30/E90 combined version and the individual versions?
The E30/E90 combined version is tested and certified to meet both the 30-minute and 90-minute standards, offering maximum flexibility and assurance for critical circuits.
5. What is the installation requirement for these cables?
They must be installed with approved cable trays and clamps to ensure they maintain circuit integrity during a fire.
6. What standards do these cables comply with?
They comply with DIN VDE 0815 (construction), IEC 332-3 (flame retardancy), DIN VDE 0472 part 814 / IEC 60331 (FE 180), and DIN VDE 4102 part 12 (E30/E90).
7. What sizes and pair configurations are available?
Available in pair configurations from 2x2x0.8mm² to 52x2x0.8mm² across all performance categories (E30, E90, and E30/E90).