AGKABEL Power Cables NYY-O/J – 0.6/1 kV, PVC Insulated, PVC Sheathed

Heavy-duty energy distribution cables designed for fixed installation in buildings and direct laying in concrete, water, and underground. Features solid or stranded copper conductors, PVC insulation, and a robust PVC outer sheath. Compliant with DIN VDE 0276 part 603. Temperature range: -5°C to +50°C (Flexing) | -30°C to +70°C (Fixed). Nominal voltage: 0.6/1 kV. Available from 1 to 5 cores, 1.5mm² to 630mm².

AGKABEL GRUPPE LIMITED presents the Power Cables NYY-O/J, engineered for reliable energy distribution in the most demanding installation environments. Designed for fixed installation in buildings, these cables are also suitable for direct laying in concrete, water, and below ground. The robust PVC construction provides excellent mechanical protection and durability, making them ideal for infrastructure and industrial power supply.

Technical Data

  • Standard: DIN VDE 0276 part 603

  • Temperature range:

    • Flexing: -5°C to +50°C

    • Fixed installation: -30°C to +70°C

  • Nominal voltage: 0.6/1 kV

  • Application: Energy distribution cable for fixed installation in buildings, for direct laying in concrete, water and below ground.

Technical Specifications Table (Sample Sizes)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
Single Core (1x)
12001062 1X4 RE 8,0 38,00 130,00
12001190 1X6 RE 8,0 58,00 150,00
12001086 1X10 RE 9,0 96,00 200,00
12001095 1X16 RE 10,0 154,00 270,00
12001105 1X25 RM 12,0 240,00 400,00
12001115 1X35 RM 13,0 336,00 500,00
12001127 1X50 RM 15,0 480,00 650,00
12001137 1X70 RM 16,0 672,00 850,00
12001145 1X95 RM 19,0 912,00 1.150,00
12001152 1X120 RM 20,0 1.152,00 1.400,00
12001158 1X150 RM 22,0 1.440,00 1.700,00
12001163 1X185 RM 25,0 1.776,00 2.100,00
12001169 1X240 RM 27,0 2.304,00 2.650,00
12001175 1X300 RM 30,0 2.880,00 3.300,00
12001181 1X400 RM 34,0 3.840,00 4.150,00
12001182 1X500 RM 34,0 4.800,00 5.200,00
12001184 1X630 RM 44,0 6.048,00 6.650,00
Multicore (2x to 4x)
12001001 2X1,5 RE 12,0 29,00 230,00
12001038 2×2,5 RE 13,0 48,00 270,00
12001064 2X4 RE 15,0 77,00 370,00
12001075 2X6 RE 16,0 115,00 450,00
12001087 2X10 RE 17,0 192,00 570,00
12001097 2X16 RE 19,0 307,00 720,00
12001107 2X25 RM 23,0 480,00 1.050,00
12001003 3X1,5 RE 13,0 43,00 250,00
12001042 3X2,5 RE 14,0 72,00 300,00
12001066 3X4 RE 15,0 115,00 400,00
12001088 3X10 RE 18,0 288,00 660,00
12001099 3X16 RE 20,0 461,00 880,00
12001110 3X25 RM 24,0 720,00 1.350,00
12001118 3X35 SM 25,0 1.008,00 1.500,00
12001130 3X50 SM 28,0 1.440,00 2.000,00
12001171 3X240 SM 50,0 6.912,00 8.300,00
4-Core & 5-Core
12001009 4X1,5 RE 13,0 58,00 300,00
12001187 4X2,5 RE 14,0 96,00 350,00
12001068 4X4 RE 16,0 154,00 480,00
12001079 4X6 RE 18,0 230,00 600,00
12001090 4X10 RE 20,0 384,00 800,00
12001101 4X16 RE 22,0 614,00 1.100,00
12001112 4X25 RM 26,0 960,00 1.600,00
12001191 4X35 SM 27,0 1.344,00 1.950,00
12001134 4X50 SM 31,0 1.920,00 2.550,00
12001142 4X70 SM 35,0 2.688,00 3.450,00
12001149 4X95 SM 40,0 3.648,00 4.600,00
12001156 4X120 SM 44,0 4.608,00 5.600,00
12001160 4X150 SM 48,0 5.760,00 7.000,00
12001167 4X185 SM 53,0 7.104,00 8.700,00
12001173 4X240 SM 60,0 9.216,00 11.300,00
12001014 7X1,5 RE 15,0 101,00 350,00
12001045 7X2,5 RE 16,0 168,00 420,00
12001017 10X1,5 RE 18,0 144,00 410,00
12001025 12X1,5 RE 19,0 173,00 460,00
12001033 14X1,5 RE 25,0 202,00 520,00

(Further dimensions available on request.)

 

Factory Overview


Packaging & Shipping


❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for these cables?
They are designed for energy distribution and fixed installation in buildings, and are suitable for direct laying in concrete, water, and below ground.

2. What is the temperature range of these cables?

  • Flexing: -5°C to +50°C

  • Fixed installation: -30°C to +70°C

3. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV.

4. What standard do these cables comply with?
They comply with DIN VDE 0276 part 603.

5. What materials are used for the conductor and insulation?
The conductor is copper (solid RE or stranded RM/SM), and the insulation and sheath are made of PVC.

6. Can these cables be laid directly in water?
Yes, they are specifically designed for direct laying in water, as well as in concrete and underground.

7. What sizes and core configurations are available?
Available from 1 to 5 cores (and up to 14 cores in some sizes), with conductor sizes ranging from 1.5mm² to 630mm².

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Power Cables NYY-O/J – 0.6/1 kV, PVC Insulated, PVC Sheathed”

Your email address will not be published. Required fields are marked *