AGKABEL Flexible Control Cables YSLY/EB-OZ – Blue Outer Jacket (Intrinsic Safety)
Number-coded flexible control cables designed for hazardous areas, featuring a special blue outer jacket for intrinsic safety identification. Extensively oil-resistant and not suitable for laying underground. Temperature range: -5°C to +80°C (Flexing) | -40°C to +80°C (Fixed). Nominal voltage: 300/500V. Available from 2 to 100 cores, 0.75mm² to 1.5mm².
AGKABEL GRUPPE LIMITED presents the Flexible Control Cables YSLY/EB-OZ, engineered for safety and reliability in hazardous environments. These cables are used for hazardous areas with special marking (blue), functioning as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit.
Technical Data
-
Temperature range:
-
Flexing: -5°C to +80°C
-
Fixed installation: -40°C to +80°C
-
-
Nominal voltage U0/U: 300/500 V
-
Test voltage: 3000 V
-
Insulation resistance min.: 20 MOhm x km
-
Minimum bending radius: 7.5 x cable diam.
-
Application: For hazardous areas with special marking (blue). Used as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Not suitable for laying below ground. Extensively oil-resistant.
Technical Specifications Table (0.75mm² Cores)
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 10104003 | 2X0,75 | 5,5 | 14,40 | 46,00 |
| 10104033 | 3X0,75 | 5,8 | 21,60 | 54,00 |
| 10104035 | 4X0,75 | 6,6 | 29,00 | 66,00 |
| 10104006 | 5X0,75 | 7,5 | 36,00 | 80,00 |
| 10104007 | 7X0,75 | 8,1 | 50,00 | 110,00 |
| 10104008 | 12X0,75 | 11,2 | 86,00 | 176,00 |
| 10104009 | 18X0,75 | 12,0 | 130,00 | 257,00 |
| 10104010 | 25X0,75 | 16,7 | 180,00 | 365,00 |
| 10104054 | 34X0,75 | 16,4 | 245,00 | 510,00 |
| 10104056 | 41X0,75 | 17,6 | 298,00 | 607,00 |
Technical Specifications Table (1.0mm² Cores)
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 10104011 | 2X1 | 5,8 | 19,20 | 53,00 |
| 10104032 | 3X1 | 6,2 | 29,00 | 67,00 |
| 10104013 | 4X1 | 6,9 | 38,40 | 81,00 |
| 10104014 | 5X1 | 7,8 | 48,00 | 103,00 |
| 10104015 | 6X1 | 8,6 | 57,60 | 120,00 |
| 10104016 | 7X1 | 8,7 | 67,00 | 133,00 |
| 10104017 | 12X1 | 11,7 | 115,00 | 225,00 |
| 10104018 | 18X1 | 14,3 | 173,00 | 334,00 |
| 10104019 | 24X1 | 17,4 | 230,40 | 495,00 |
| 10104020 | 25X1 | 17,5 | 240,00 | 500,00 |
| 10104055 | 41X1 | 21,4 | 394,00 | 770,00 |
| 10104021 | 56X1 | 24,0 | 537,60 | 920,00 |
| 10104058 | 100X1 | 31,0 | 960,00 | 1.645,00 |
Technical Specifications Table (1.5mm² Cores)
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 10104022 | 2X1,5 | 6,6 | 29,00 | 70,00 |
| 10104023 | 3X1,5 | 7,0 | 43,00 | 86,00 |
| 10104024 | 4X1,5 | 7,9 | 58,00 | 109,00 |
| 10104025 | 5X1,5 | 8,8 | 72,00 | 130,00 |
| 10104026 | 7X1,5 | 9,8 | 101,00 | 178,00 |
| 10104027 | 12X1,5 | 13,6 | 173,00 | 305,00 |
| 10104028 | 18X1,5 | 16,4 | 259,00 | 430,00 |
| 10104029 | 25X1,5 | 19,4 | 360,00 | 620,00 |
| 10104031 | 34X1,5 | 21,6 | 490,00 | 820,00 |
| 10104030 | 32X1,5 | 15,9 | 461,00 | 780,00 |
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for this cable?
It is used for hazardous areas with special marking (blue), functioning as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus.
2. What is the temperature range of this cable?
-
Flexing: -5°C to +80°C
-
Fixed installation: -40°C to +80°C
3. What is the significance of the blue outer jacket?
The blue outer jacket is a special marking used to identify cables suitable for intrinsically safe circuits in hazardous areas.
4. What is the voltage rating of this cable?
The nominal voltage is 300/500 V and the test voltage is 3000 V.
5. Is this cable suitable for underground installation?
No, it is not suitable for laying below ground.
6. What are the key physical properties of this cable?
It is extensively oil-resistant and has a minimum bending radius of 7.5 x cable diameter.
7. What sizes and core configurations are available?
Available from 2 to 100 cores, with conductor sizes of 0.75mm², 1.0mm², and 1.5mm².
8. Are there special requirements for installation?
Yes, these installations are not earthed and require a separate power circuit.







Reviews
There are no reviews yet.