AGKABEL Flexible Control Cables YSLY/EB-OZ – Blue Outer Jacket (Intrinsic Safety)

Number-coded flexible control cables designed for hazardous areas, featuring a special blue outer jacket for intrinsic safety identification. Extensively oil-resistant and not suitable for laying underground. Temperature range: -5°C to +80°C (Flexing) | -40°C to +80°C (Fixed). Nominal voltage: 300/500V. Available from 2 to 100 cores, 0.75mm² to 1.5mm².

AGKABEL GRUPPE LIMITED presents the Flexible Control Cables YSLY/EB-OZ, engineered for safety and reliability in hazardous environments. These cables are used for hazardous areas with special marking (blue), functioning as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit.

Technical Data

  • Temperature range:

    • Flexing: -5°C to +80°C

    • Fixed installation: -40°C to +80°C

  • Nominal voltage U0/U: 300/500 V

  • Test voltage: 3000 V

  • Insulation resistance min.: 20 MOhm x km

  • Minimum bending radius: 7.5 x cable diam.

  • Application: For hazardous areas with special marking (blue). Used as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Not suitable for laying below ground. Extensively oil-resistant.

Technical Specifications Table (0.75mm² Cores)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
10104003 2X0,75 5,5 14,40 46,00
10104033 3X0,75 5,8 21,60 54,00
10104035 4X0,75 6,6 29,00 66,00
10104006 5X0,75 7,5 36,00 80,00
10104007 7X0,75 8,1 50,00 110,00
10104008 12X0,75 11,2 86,00 176,00
10104009 18X0,75 12,0 130,00 257,00
10104010 25X0,75 16,7 180,00 365,00
10104054 34X0,75 16,4 245,00 510,00
10104056 41X0,75 17,6 298,00 607,00

Technical Specifications Table (1.0mm² Cores)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
10104011 2X1 5,8 19,20 53,00
10104032 3X1 6,2 29,00 67,00
10104013 4X1 6,9 38,40 81,00
10104014 5X1 7,8 48,00 103,00
10104015 6X1 8,6 57,60 120,00
10104016 7X1 8,7 67,00 133,00
10104017 12X1 11,7 115,00 225,00
10104018 18X1 14,3 173,00 334,00
10104019 24X1 17,4 230,40 495,00
10104020 25X1 17,5 240,00 500,00
10104055 41X1 21,4 394,00 770,00
10104021 56X1 24,0 537,60 920,00
10104058 100X1 31,0 960,00 1.645,00

Technical Specifications Table (1.5mm² Cores)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
10104022 2X1,5 6,6 29,00 70,00
10104023 3X1,5 7,0 43,00 86,00
10104024 4X1,5 7,9 58,00 109,00
10104025 5X1,5 8,8 72,00 130,00
10104026 7X1,5 9,8 101,00 178,00
10104027 12X1,5 13,6 173,00 305,00
10104028 18X1,5 16,4 259,00 430,00
10104029 25X1,5 19,4 360,00 620,00
10104031 34X1,5 21,6 490,00 820,00
10104030 32X1,5 15,9 461,00 780,00

 

Factory Overview


Packaging & Shipping


 

Fly

 

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for this cable?
It is used for hazardous areas with special marking (blue), functioning as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus.

2. What is the temperature range of this cable?

  • Flexing: -5°C to +80°C

  • Fixed installation: -40°C to +80°C

3. What is the significance of the blue outer jacket?
The blue outer jacket is a special marking used to identify cables suitable for intrinsically safe circuits in hazardous areas.

4. What is the voltage rating of this cable?
The nominal voltage is 300/500 V and the test voltage is 3000 V.

5. Is this cable suitable for underground installation?
No, it is not suitable for laying below ground.

6. What are the key physical properties of this cable?
It is extensively oil-resistant and has a minimum bending radius of 7.5 x cable diameter.

7. What sizes and core configurations are available?
Available from 2 to 100 cores, with conductor sizes of 0.75mm², 1.0mm², and 1.5mm².

8. Are there special requirements for installation?
Yes, these installations are not earthed and require a separate power circuit.